Thomas T. Nigamatzyanov
|
Teplokontrol JSC |
Kazan, Russian Fereration tomas-nigmat@mail.ru |
Valery V. Askerkov
|
Teplokontrol JSC |
omk-tk@mail.ru |
Sergey G. Lebedev
|
SCB Pribor, Teplokontrol JSC |
Kazan, Russian Fereration sergl-64@mail.ru |
Rustem R. Salimullin
|
Engineering Center of JSC Tatneft |
Almetyevsk, Russian Fereration salimullin@tatneft.ru |
Alexander A. Yevseyev
|
JSC Tatneft |
Almetyevsk, Russian Fereration |
Ramil R. Kurbangaliev
|
JSC Tatneft, NGDU Almetyevneft |
Almetyevsk, Russian Fereration |
Rezeda G. Gaisina
|
SCB Pribor, Teplokontrol JSC |
Kazan, Russian Fereration sergl-64@mail.ru |
The article considers the results of experienced operational tests before and after theconstructive developments converters hydrostatic pressure Sapphire-22-MP-VN-DG installed on the tanks filling installations which are used for the measurement of mass flow corrosion inhibitor supplied in oilfield equipment.
Materials and methods
Reagent used in filling plants Almetievsk oil and gas production OJSC «Tatneft» corrosion inhibitor. Volumetric-mass method for DH-781,method using hydrostatic pressure transducer described in [2].
Results
According to the results of experienced operational tests established that thetransmitter of the hydrostatic pressure Sapphire-22-MP-VN-DG measures the mass flow in reagent reservoirs filling installations with a relativeerror, not exceeding a value of ±0.1%.
Сonclusions
Hydrostatic pressure transmitters Sapphire-22-MP-VN-DG with a limit of permissible basic error ±0.15% of full scale, produced by OJSC Teplokontrol may be used for continuous measurement and monitoring of the mass of the reagent and oil products, and also for use output parameters to control technological processes.
transmitter of the hydrostatic pressure sensor
mass flow
corr