Grigoriy M. Dolgikh | Ph.D., general director | NPO Fundamentstroyarkos LLC, Tyumen, Russia fsa@npo-fsa.ru |
Sergey N. Okunev | Ph.D., chief engineer | NPO Fundamentstroyarkos LLC, Tyumen, Russia fsa@npo-fsa.ru |
The article assesses the efficiency of the GTT system (horizontal pipe in the pipe) at different positions of the cooling pipes with a closed end (TOZK). Within the framework of studies tests were carried out at three positions of the TOZK: horizontal, slightly inclined (their far end is lowered by 0.5 m) and anti-inclined (their far end is raised by 0.5 m), at various thermal loads.